Glossary entry (derived from question below)
English term or phrase:
40A make/break (relay)
French translation:
commutations (ou òperations de commutation) à 40 A
Added to glossary by
Johannes Gleim
Jul 17, 2023 08:09
11 mos ago
25 viewers *
English term
40A make/break (relay)
English to French
Tech/Engineering
Electronics / Elect Eng
Relays
The new XX extends the existing XX relay capability by increasing the rated carry current from 100A to 120A and enabling 30000 operations with 40A make/break and 120A carry currents.
This is a PR on a new relay
This is a PR on a new relay
Proposed translations
(French)
5 -1 | commutations (ou òperations de commutation) à 40 A | Johannes Gleim |
3 +2 | intensité de coupure / établi | Tony M |
3 -1 | Relais à coupure/mise en marche de 40A | Sakshi Garg |
Change log
Jul 25, 2023 10:29: Johannes Gleim Created KOG entry
Proposed translations
-1
3 hrs
Selected
commutations (ou òperations de commutation) à 40 A
Pour traduire correctement ce texte truffé de termes électrotechniques, il faut d'abord les connaître et savoir de quoi il s'agit. C'est pourquoi je donne d'abord les définitions avec les désignations normalisées :
Area Electrical accessories / General
IEV ref 442-01-02
en rated current (for accessories)
the current assigned by the manufacturer for a specified operating condition of an accessory
fr courant assigné (pour le petit appareillage) m
courant fixé par le constructeur pour le fonctionnement spécifié d'un appareil
https://www.electropedia.org/iev/iev.nsf/display?openform&ie...
Area Electrical accessories / General
IEV ref 442-01-48
en making capacity
a value of prospective current that a switching device is capable of making at a stated voltage under prescribed conditions of use and behaviour
fr
pouvoir de fermeture, m
valeur du courant présumé qu'un dispositif de coupure est capable d'établir sous une tension donnée et dans des conditions prescrites d'emploi et de comportement
https://www.electropedia.org/iev/iev.nsf/display?openform&ie...
Area Switchgear, controlgear and fuses / Characteristic quantities of switchgear, controlgear and fuses
IEV ref 441-17-08
en breaking capacity (of a switching device or a fuse)
a value of prospective current that a switching device or a fuse is capable of breaking at a stated voltage under prescribed conditions of use and behaviour
fr pouvoir de coupure (d'un appareil de connexion ou d'un fusible)
une valeur de courant présumé qu'un appareil de connexion ou un fusible est capable d'interrompre sous une tension fixée dans des conditions prescrites d'emploi et de comportement
https://www.electropedia.org/iev/iev.nsf/display?openform&ie...
Area Switchgear, controlgear and fuses / Characteristic quantities of switchgear, controlgear and fuses
IEV ref 441-17-07
en breaking current (of a switching device or a fuse)
the current in a pole of a switching device or in a fuse at the instant of initiation of the arc during a breaking process
fr courant coupé (d'un appareil de connexion ou d'un fusible) m
courant dans un pôle d'un appareil de connexion ou dans un fusible évalué à l'instant de l'amorçage de l'arc au cours d'une coupure
https://www.electropedia.org/iev/iev.nsf/display?openform&ie...
Area Elementary relays / Output circuits
IEV ref 444-04-20
en change-over make-before-break contact
change-over contact in which the make contact circuit closes before the break contact circuit opens
fr contact à deux directions avec chevauchement, m
contact à deux directions dont le circuit de contact de travail se ferme avant que le circuit de contact de repose s'ouvre
https://www.electropedia.org/iev/iev.nsf/display?openform&ie...
Area Measuring relays / Terms relating to output circuits
IEV ref 447-04-10
en make contact
contact that is closed when the measuring relay or protection equipment is in its operate condition and that is open when the relay or protection equipment is in its reset condition
fr contact de travail, m
contact fermé lorsque le relais de mesure ou l'équipement de protection est à l'état de travail et ouvert lorsque le relais ou l'équipement est à l'état de repos
https://www.electropedia.org/iev/iev.nsf/display?openform&ie...
Area Electrical installations / Voltages and currents
IEV ref 826-11-13
en current-carrying capacity; ampacity, US
maximum value of electric current which can be carried continuously by a conductor, a device or an apparatus, under specified conditions without its steady-state temperature exceeding a specified value
fr courant permanent admissible, m ; courant admissible, m
valeur maximale du courant électrique qui peut parcourir en permanence, un conducteur, un dispositif ou un appareil, sans que sa température de régime permanent, dans des conditions données, soit supérieure à la valeur spécifiée
https://www.electropedia.org/iev/iev.nsf/display?openform&ie...
Durée de vie mécanique
sans charge min. 1.000.000 commutations (60 commutations / min.)
sous charge min. 30.000 commutations (30 commutations / min.)
https://www.google.de/url?sa=t&rct=j&q=&esrc=s&source=web&cd...
Avec le module sortie à relais 4x DALI-RM/S 4x10A , il est possible de commander des luminaires ou des autres charges avec tension secteur 230/240 V max.
:
Spécifications concernant les charges établies pour 30.000 commutations
https://resources.tridonic.com/PDB/Ressource/Web_TR/brochure...
Il utilise des relais électromécaniques pour effectuer des opérations de commutation immédiates dans l'une des configurations de multiplexeur 2 fil suivantes:
https://ch.farnell.com/fr-CH/ni/780587-25/pxi-multiplexer-sc...
Mais les temps de commutation ne représentent ici qu’un seul côté de la médaille car il faut également prendre en compte le nombre d’opérations de commutation possibles.
https://scdn.rohde-schwarz.com/ur/pws/dl_downloads/dl_common...
Les interrupteurs à clé des deux séries se caractérisent par une grande robustesse et une très faible résistance de contact dans la gamme des milliohms. En outre, ils offrent une longue durée de vie de 30 000 opérations de commutation.
https://alders.de/fr/produits/bouton-de-commutation/interrup...
Proposal for context translation:
Le nouveau XX étend les capacités de la gamme de relais XX existante en augmentant le courant assigné (ou admissible) de 100 A à 120 A en établissant 30.000 opérations de commutation à 40 A et 120 A de courant admissible.
Area Electrical accessories / General
IEV ref 442-01-02
en rated current (for accessories)
the current assigned by the manufacturer for a specified operating condition of an accessory
fr courant assigné (pour le petit appareillage) m
courant fixé par le constructeur pour le fonctionnement spécifié d'un appareil
https://www.electropedia.org/iev/iev.nsf/display?openform&ie...
Area Electrical accessories / General
IEV ref 442-01-48
en making capacity
a value of prospective current that a switching device is capable of making at a stated voltage under prescribed conditions of use and behaviour
fr
pouvoir de fermeture, m
valeur du courant présumé qu'un dispositif de coupure est capable d'établir sous une tension donnée et dans des conditions prescrites d'emploi et de comportement
https://www.electropedia.org/iev/iev.nsf/display?openform&ie...
Area Switchgear, controlgear and fuses / Characteristic quantities of switchgear, controlgear and fuses
IEV ref 441-17-08
en breaking capacity (of a switching device or a fuse)
a value of prospective current that a switching device or a fuse is capable of breaking at a stated voltage under prescribed conditions of use and behaviour
fr pouvoir de coupure (d'un appareil de connexion ou d'un fusible)
une valeur de courant présumé qu'un appareil de connexion ou un fusible est capable d'interrompre sous une tension fixée dans des conditions prescrites d'emploi et de comportement
https://www.electropedia.org/iev/iev.nsf/display?openform&ie...
Area Switchgear, controlgear and fuses / Characteristic quantities of switchgear, controlgear and fuses
IEV ref 441-17-07
en breaking current (of a switching device or a fuse)
the current in a pole of a switching device or in a fuse at the instant of initiation of the arc during a breaking process
fr courant coupé (d'un appareil de connexion ou d'un fusible) m
courant dans un pôle d'un appareil de connexion ou dans un fusible évalué à l'instant de l'amorçage de l'arc au cours d'une coupure
https://www.electropedia.org/iev/iev.nsf/display?openform&ie...
Area Elementary relays / Output circuits
IEV ref 444-04-20
en change-over make-before-break contact
change-over contact in which the make contact circuit closes before the break contact circuit opens
fr contact à deux directions avec chevauchement, m
contact à deux directions dont le circuit de contact de travail se ferme avant que le circuit de contact de repose s'ouvre
https://www.electropedia.org/iev/iev.nsf/display?openform&ie...
Area Measuring relays / Terms relating to output circuits
IEV ref 447-04-10
en make contact
contact that is closed when the measuring relay or protection equipment is in its operate condition and that is open when the relay or protection equipment is in its reset condition
fr contact de travail, m
contact fermé lorsque le relais de mesure ou l'équipement de protection est à l'état de travail et ouvert lorsque le relais ou l'équipement est à l'état de repos
https://www.electropedia.org/iev/iev.nsf/display?openform&ie...
Area Electrical installations / Voltages and currents
IEV ref 826-11-13
en current-carrying capacity; ampacity, US
maximum value of electric current which can be carried continuously by a conductor, a device or an apparatus, under specified conditions without its steady-state temperature exceeding a specified value
fr courant permanent admissible, m ; courant admissible, m
valeur maximale du courant électrique qui peut parcourir en permanence, un conducteur, un dispositif ou un appareil, sans que sa température de régime permanent, dans des conditions données, soit supérieure à la valeur spécifiée
https://www.electropedia.org/iev/iev.nsf/display?openform&ie...
Durée de vie mécanique
sans charge min. 1.000.000 commutations (60 commutations / min.)
sous charge min. 30.000 commutations (30 commutations / min.)
https://www.google.de/url?sa=t&rct=j&q=&esrc=s&source=web&cd...
Avec le module sortie à relais 4x DALI-RM/S 4x10A , il est possible de commander des luminaires ou des autres charges avec tension secteur 230/240 V max.
:
Spécifications concernant les charges établies pour 30.000 commutations
https://resources.tridonic.com/PDB/Ressource/Web_TR/brochure...
Il utilise des relais électromécaniques pour effectuer des opérations de commutation immédiates dans l'une des configurations de multiplexeur 2 fil suivantes:
https://ch.farnell.com/fr-CH/ni/780587-25/pxi-multiplexer-sc...
Mais les temps de commutation ne représentent ici qu’un seul côté de la médaille car il faut également prendre en compte le nombre d’opérations de commutation possibles.
https://scdn.rohde-schwarz.com/ur/pws/dl_downloads/dl_common...
Les interrupteurs à clé des deux séries se caractérisent par une grande robustesse et une très faible résistance de contact dans la gamme des milliohms. En outre, ils offrent une longue durée de vie de 30 000 opérations de commutation.
https://alders.de/fr/produits/bouton-de-commutation/interrup...
Proposal for context translation:
Le nouveau XX étend les capacités de la gamme de relais XX existante en augmentant le courant assigné (ou admissible) de 100 A à 120 A en établissant 30.000 opérations de commutation à 40 A et 120 A de courant admissible.
Note from asker:
Thanks Johannes, for rated carry current, the key term is carry current, not rated current (for instance, def in https://forum.digikey.com/t/switching-current-vs-carry-current-in-a-reed-switch/726). Carry current = courant passant, for instance https://www.celduc-relais.com/Technical_DataSheet/FT_PTFA3115.pdf) |
Peer comment(s):
neutral |
Schtroumpf
: Et où dans cette réponse-fleuve trouvera-t-on l'explication pour "make / break" ? Juste pour nous éviter de lire trois pages sans intérêt pour la question.
3 hrs
|
Pour faciliter la lecture par les pairs, j'ai mis en évidence les mots-clés les plus importants. Ceux qui savent lire comprennent.
|
|
disagree |
Tony M
: 'commutation' is under-translation here, and implies that the M/B currents are symmetrical, which is often not the case; this MUST be made clear.
4 hrs
|
Usually, the information on 'make/break' refers to resistive circuits. Reactive loads would reduce the number depending on the phase shift.
|
4 KudoZ points awarded for this answer.
-1
58 mins
Relais à coupure/mise en marche de 40A
https://dc2kentprodcontent.blob.core.windows.net/sequenceman...
https://boulanger.scene7.com/is/content/Boulanger/4242003926...
https://www.manualslib.de/manual/39050/Silvercrest-54385.htm...
Peer comment(s):
disagree |
Johannes Gleim
: Il s'agirait d'un relais de mise en marche/arrêt. Mais il s'agit ici de la durée de vie de 30 000 commutations.
2 hrs
|
+2
1 hr
English term (edited):
40A make/break
intensité de coupure / établi
Of course it is the current rating that is 40 A, not the actual relay per se!
We also find 'courant', but I think 'intensité' is probably better in specifications like this
I have also come across 'courant/intensité d'enclenchement', but I'm not entirely sure that refers to the same thing; ditto 'courant d'appel', which is more strictly 'inrush current'.
We also find 'courant', but I think 'intensité' is probably better in specifications like this
I have also come across 'courant/intensité d'enclenchement', but I'm not entirely sure that refers to the same thing; ditto 'courant d'appel', which is more strictly 'inrush current'.
Peer comment(s):
agree |
Schtroumpf
: Ça va dans cette direction : make / break -> à l'appel / à la retombée, https://www.chauvin-arnoux-energy.com/sites/default/files/do...
5 hrs
|
Merci, Schtroumpf !
|
|
agree |
Kim Metzger
6 hrs
|
Thanks, Kim!
|
|
neutral |
Johannes Gleim
: 'intensité' is not the standard translation für 'current'. https://www.electropedia.org/iev/iev.nsf/display?openform&ie...
2 days 3 hrs
|
Discussion